The KICD01 intelligent humidifier (hereinafter referred to as the device) is a kind of dehumidifying device developed by our company for many years' field dehumidification experience. The device is developed by the principle of semiconductor thermoelectric conversion, which can hold more water by heating the air through the hot end, and draw the hot air to the cold end, so that the air is suddenly cooled and condensed. For small water beads, the controller uses microcomputers to control the water after collecting water through an internal water collector to remove the cabinet. The control mode is varied. In addition to the semiconductor thermoelectric dehumidification mode, it also has the parameters of the temperature and humidity outside the monitoring cabinet and the functions of forced ventilation and dehumidification.
The KICD01 intelligent humidifier (hereinafter referred to as the device) is a kind of dehumidifying device developed by our company for many years' field dehumidification experience. The device is developed by the principle of semiconductor thermoelectric conversion, which can hold more water by heating the air through the hot end, and draw the hot air to the cold end, so that the air is suddenly cooled and condensed. For small water beads, the controller uses microcomputers to control the water after collecting water through an internal water collector to remove the cabinet. The control mode is varied. In addition to the semiconductor thermoelectric dehumidification mode, it also has the parameters of the temperature and humidity outside the monitoring cabinet and the functions of forced ventilation and dehumidification.
The humidifier has the characteristics of remarkable dehumidification effect, low energy consumption, good stability, small volume and convenient installation and use. It is a good substitute for the traditional heating controller. The device is widely used in high and low voltage distribution cabinet, distribution box, branch box, terminal box, box change and communication cabinet and so on. It solves the phenomenon of excessive humidity or condensation in the cabinet to produce fault hidden trouble or corrosion of equipment. It can prevent the insulation reduction in the equipment, electrical discharge, electrical connection point oxidation, metal corrosion, mechanism aging and hair. Mildew and so on.
Dehumidification effect is significant, energy consumption is low, maximum 35W power consumption.
During the working process, the internal temperature rise of the equipment will not be caused, and the hidden danger caused by the high temperature of the heater surface and the influence of the temperature rise inside the cabinet on the equipment will be solved.
Small size, light weight, easy and quick installation, automatic operation and manual dehumidification switch, temperature start value and dehumidification start value adjustable.
Design various power supply modes and products. Users can choose AC220V, 110V and solar panels to supply power.
It is difficult to solve the problem of power collection in user's actual use.
Product installation: 35mm standard guide type installation.
Water pipe installation: connect the water pipe to the right length to punch holes at the bottom of the cabinet or to find suitable drainage pipes.
Location will lead to drain pipe, if there are multiple products in the same indoor use, we should consider the centralized drainage method. (special hint: the pipe is strictly prohibited to coiling so as to avoid clogging)
1. function description
1) air convection function: the humidifier is connected to the power supply, the fan is opened immediately, and the air flow in the cabinet will be circulated for 3 minutes before measuring the humidity value, so that the measurement of humidity is more accurate.
2) automatic dehumidification function: when the humidifier can measure the humidity greater than the set value through a matching high precision humidity sensor, the dehumidification function starts automatically, and the running indicator is opened at the same time, when the humidity is measured.
Below the set humidity minus 10%RH, the dehumidification function stops automatically, while the running indicator is turned off.
3) alarm instructions:
3-1: the refrigeration block temperature detection circuit malfunction, the left digital tube displays ET1, the fault indicator lights up.
3-2: fan fault, the left digital display ET4, the fault light is lit, the fault indicator lights up.
3-3: after 3 minutes of wetting device, the surface temperature of the cooling block is more than 60 centigrade for 1.5 seconds. The default cooling block is damaged. The left digital tube displays ET5 and closes the working power of the refrigeration block. This function repeats the surface temperature of the cooling block with the cycle of 30 minutes.
4) manual dehumidification: press and hold the add and drop key for 3 seconds at the same time, forced dehumidification, start the manual light to light, refrigerate block start, fan start, and then deactivate manual dehumidification by 3 seconds.
After-sale and service
1, all products are guaranteed free for one year, life-long maintenance.
2. Reply to the problem within 24 hours. If there are major technical problems, the company will send technicians to solve the problem at the fastest speed.
3. In the process of pre-sale, sale and after sale, the relevant matters related to the application and design of the related products are accurately and promptly answered, and the corresponding technical support is provided.
Technical parameter:
Layout, installation and wiring